Unstoppable 125 to 200 kVA Power for High-Demand Environments Like Hospitals, Function Halls, Factories and Supermarkets

Built for the toughest loads. Our 125-200kVA kVA DG sets combine VECV (Volvo Eicher) global engine technology with Standard IoT Remote Monitoring and CPCB IV+ compliance.

Suitable Industry & Application

Find the perfect power match for your sector. We provide tailored 125-200 kVA backup solutions designed to meet the unique load demands of diverse industries across South India.

img0705261730 1

Hospitals

Reliable backup power for uninterrupted critical healthcare operations.

img0705261730 3

Function Halls

Seamless power for grand events and celebrations

img2104261305 4

Factories

High-torque energy for relentless industrial production.

img0705261730 2

Supermarkets

Continuous energy for smooth retail and cooling operation.

Elmot PowerGen Highlights

Unmatched fuel efficiency, IOT monitoring is standard from 125 kVA, and localized manufacturing make Elmot PowerGen the smartest choice for backup power. Explore the technical highlights that set our 125 –200 kVA diesel generators apart, ensuring lower total cost of ownership and 100% emission compliance.

icon engine tech

Engine Technology

VECV with IOT monitoring

icon emission std

Emission Standard

CPCB IV+ Compliant 

icon enclosure

Enclosure

Powder coated ideal for costal areas

icon max uptime

Maximum Uptime

Reliable, uninterrupted power performance

icon 6cylinder adv

6 Cylinder Advantage

Higher efficiency, smoother performance

icon service resp

Service Response

2–3 Hrs (Local) / 6–24 Hrs (Remote)

icon noise lev

Noise Level

<75 db(A) Ideal for residential areas

icon min fuel burn

Minimum Fuel Burn

Optimized efficiency, lower fuel consumption

Technical Spotlight

Explore the cutting-edge engineering behind Elmot PowerGen’s 10-200 kVA range, featuring CPCB IV+ compliance and smart-load sensing. See how our advanced fuel-mapping technology delivers maximum uptime with whisper-quiet performance.

Feature125 kVA160 kVA180 kVA
DG SetPower Rating125 kVA / 100 kW160kva/128kw180kva/144kw
Emission NormsCPCB IV+ CompliantCPCB IV+ CompliantCPCB IV+ Compliant
Fuel Consumption~20.1 Ltrs/Hr @ 75% Load~27.1 Ltrs/Hr @ 75% Load~31.1 Ltrs/Hr @ 75% Load
B-Check Interval Hours/ Months700Hr or 1 year which ever is earlier700Hr or 1 year which ever is earlier700Hr or 1 year which ever is earlier
Control Panel (Mode)Manual (AMF Module is standard)Manual (AMF Module is standard)Manual (AMF Module is standard)
Genset Dimensions (LXBXH)3400x1250x15003900x1400x18003900x1400x1800
Genset Weight (kg)2016Kg2380Kg2380Kg
Engine MakeVECV (Volvo Eicher)VECV (Volvo Eicher)VECV (Volvo Eicher)
EngineCooling SystemLiquid Cooled (Radiator)Liquid Cooled (Radiator)Liquid Cooled (Radiator)
Governor TypeElectronic (A1 Class)Electronic (A1 Class)Electronic (A1 Class)
Block Load CapOver 60% Sudden Load CapacityOver 60% Sudden Load CapacityOver 60% Sudden Load Capacity
Configuration6-Cylinder, Inline6-Cylinder, Inline6-Cylinder, Inline
AspirationTurbocharged intercooledTurbocharged intercooledTurbocharged intercooled
AlternatorAlternator MakeMECCALTE LEROY SOMER STAMFORD CROMPTON GREAVEMECCALTE LEROY SOMER STAMFORD CROMPTON GREAVEMECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE
Voltage Regulation± 1% (Static)± 1% (Static)± 1% (Static)
Insulation ClassClass HClass HClass H

Enclosure & Build Quality

Engineered for extreme durability, our CPCB IV+ compliant enclosures feature heavy-duty galvanized steel, anti-corrosive powder coating, and premium acoustic insulation for maximum weather protection and ultra-silent operation.

icon sheet metal

Sheet Metal

1.5mm Heavy-Duty CRCA sheet (Competition typically use 1.2mm).

icon surface treat

Surface Treatment

9-Tank Pre-treatment with UV-Resistant Pure Polyester Powder Coating.

icon hardware

Hardware

Stainless Steel hinges and Zinc-plated fasteners for corrosion resistance

icon insulation

Insulation

High-density fire-retardant acoustic foam for Ultra-Silent Operation.

Smart Control System

Our IoT-enabled controllers, offering real-time fuel monitoring, 10-second auto-start, and predictive health alerts for 24/7 industrial uptime.

img2104261749 1

Controller

DeepSea / ComAp / WoodWard (High-end digital controllers).

img2104261749 3

Monitoring

Integrated IoT Dashboard (Real-time fuel, load, and health tracking).

img2104261749 2

Safety

Auto-shutdown for High Water Temp, Low Oil Pressure, and Over-Speed.

Frequently Asked Questions

Find expert answers to common questions regarding CPCB IV+ norms, DG set maintenance, and kVA load calculation. Get the clarity you need to make an informed investment in your facility’s backup power infrastructure.

What is the fuel consumption of a 125 kVA diesel generator per hour?

On average, a 125 kVA DG set consumes approximately 20–22 liters per hour at 75% load and about 26–28 liters per hour at 100% load. Elmot PowerGen units are optimized with precision fuel mapping to reduce these costs by up to 12%.

How many AMPS does a 125 kVA 3-phase generator produce?

A 125 kVA generator operating at a 0.8 power factor on a 415V 3-phase system produces approximately 174 Amps per phase. This makes it ideal for medium-scale industrial motors and commercial complexes.

Can a 125 kVA generator run a 50 HP motor?

Yes. A 125 kVA generator is typically sufficient to start and run a 50 HP motor, provided it is equipped with a Star-Delta starter or a VFD (Variable Frequency Drive) to manage the initial in-rush current.

What are the latest CPCB IV+ emission norms for 125 kVA generators?

CPCB IV+ is the mandatory 2026 emission standard in India. It requires 125 kVA sets to have advanced after-treatment systems (like SCR or DPF) to reduce particulate matter and Nitrogen Oxides (NOx) by over 80% compared to older CPCB II models.

What is the ideal room size or footprint for a 125 kVA silent DG set?

A standard 125 kVA silent generator with an acoustic enclosure typically requires a footprint of approximately 3200mm (L) x 1300mm (W) x 1800mm (H). For safety and ventilation, a clearance of 2 meters on all sides is recommended.

How many Air Conditioners (ACs) can a 125 kVA generator handle?

A 125 kVA unit can comfortably power 25 to 30 units of 1.5-ton 5-star inverter ACs, along with basic lighting and office equipment, making it the preferred choice for banks and small hospitals.

What is the difference between Prime Power and Standby Power for 125 kVA?

Prime Power (125 kVA) is for unlimited hours of use with variable load, while Standby Power (typically 135-140 kVA) is for emergency use during a utility power outage. Elmot PowerGen provides 125 kVA Prime-rated sets for heavy-duty industrial use.

How often does a 125 kVA generator require servicing?

Standard service intervals are every 250 to 300 running hours or every 6 months, whichever comes first. This includes changing the lube oil, fuel filters, and checking the coolant levels to ensure 99.9% uptime.

Is a 125 kVA generator suitable for a hospital or diagnostic center?

Yes. A 125 kVA generator is the "sweet spot" for small to medium hospitals. When paired with an Electronic Governor (A1 Class), it provides the stable, flicker-free power required for sensitive medical equipment like X-rays and dialysis machines.

Does a 125 kVA generator require an AMF Panel?

While not mandatory, an AMF (Auto-Mains Failure) Panel is highly recommended. It detects a grid failure and automatically starts the 125 kVA generator, restoring power in under 7–10 seconds without human intervention.

What is the noise level of a "Silent" 125 kVA DG set?

According to CPCB norms, a silent 125 kVA DG set must maintain a noise level of less than 75 dB(A) at a distance of 1 meter. Elmot’s acoustic enclosures use high-density rockwool to ensure compliance even in residential zones.

What is the warranty period for Elmot PowerGen 125 kVA generators?

We offer a comprehensive warranty of 2 years or 5000 running hours (whichever is earlier), supported by our 6-hour service guarantee across South India, including Hyderabad, Bangalore, and Vijayawada. Please check with our sales/support staff for the latest offers and warranty terms.

How does the IoT feature help in construction projects?

It allows for remote monitoring of fuel consumption and monitoring of other critical parameters, preventing unauthorised use and identifying maintenance needs before a breakdown occurs.

What is the turnaround time for emergency breakdowns?

We guarantee a 2–3 hour response for local Hyderabad complaints and 6–24 hours for remote locations. 

Reliable Energy for Every Industry

Secure your operations with precision-engineered 125–200 kVA DG sets. We deliver fuel-efficient, high-performance power that never skips a beat.