Unstoppable 40 to 62.5 kVA Power for
Restaurants, Clinics and Banks
Don't let a power cut pause your operations. Our 40–62.5 kVA range is built to handle heavy startup loads, multiple AC units, and sensitive electronics simultaneously. Reliable, fuel-efficient, and ready for 24/7 operation.
Suitable Industries & Applications
High-capacity power engineered for businesses that never close. From protecting critical medical equipment to sustaining full-scale kitchen operations and secure banking servers, our DG sets deliver industrial-grade reliability with zero compromise.

Restaurants
Protecting the cold chain and ensuring uninterrupted kitchen service.

Clinics
Seamless power to protect patient care, and data.

Banks
Reliable power for servers, ATMs, critical financial data & surveillance systems.
Elmot PowerGen Highlights
Unmatched fuel efficiency, optional IOT monitoring (on request), and localized manufacturing make Elmot PowerGen the smartest choice for backup power. Explore the technical highlights that set our 40-62.5 kVA diesel generators apart, ensuring lower total cost of ownership and 100% emission compliance.
Engine Technology
Escorts/VECV
Emission Standard
CPCB IV +
Enclosure
UV resistant coating - ideal for harsh environments
Maximum Uptime
Reliable, uninterrupted power performance
Service Response
2–3 Hrs (Local) / 6–24 Hrs (Remote)
Noise Level
<75 db(A) Ideal for residential areas
Minimum Fuel Burn
Optimized efficiency, lower fuel consumption
Technical Spotlight
Explore the cutting-edge engineering behind Elmot PowerGen’s 10-200 kVA range, featuring CPCB IV+ compliance and smart-load sensing.
See how our advanced fuel-mapping technology delivers maximum uptime with whisper-quiet performance.
| Feature | 40 kVA | 45 kVA | 62.5 kVA | What It Means for You | |
|---|---|---|---|---|---|
| DG Set | Power Rating | 40kva/32kw | 45kva/36kw | 62.5kva/50kw | |
| Emission Norms | CPCB IV+ Compliant | CPCB IV+ Compliant | CPCB IV+ Compliant | ||
| Fuel Consumption | 6.9 Ltrs/Hr @ 75% Load | 7.1 Ltrs/Hr @ 75% Load | 9.7 Ltrs/Hr @ 75% Load | ||
| B-Check Interval. Hours/ Months | 500Hr or 3 months which ever is earlier | 500Hr or 3 months which ever is earlier | 500Hr or 3 months which ever is earlier | ||
| Control Panel (Mode) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | ||
| Genset Dimensions (LXBXH) | 1900 X 1000 X 1350 | 1900 X 1000 X 1350 | 2800 X 1100 X 1500 | ||
| Genset Weight (kg) | 992Kg | 992Kg | 1355Kg | ||
| Engine Make | Escorts kubota | Escorts kubota | Escorts kubota | ||
| Engine | Cooling System | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | |
| Governor Type | Electronic (“A1”) | Electronic (“A1”) | Electronic (“A1”) | ||
| Block Load Cap | Over 50% Sudden Load Capacity | Over 50% Sudden Load Capacity | Over 50% Sudden Load Capacity | ||
| Configuration | 3Cylinder, Inline | 3Cylinder, Inline | 4-Cylinder, Inline | ||
| Aspiration | Turbocharged intercooled | Turbocharged intercooled | Turbocharged intercooled | ||
| Alternator | Alternator Make | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | |
| Voltage Regulation | ± 1% (Static) | ± 1% (Static) | ± 1% (Static) | ||
| Insulation Class | Class H | Class H | Class H |
| Feature | 40 kVA | 45 kVA | 60 kVA | What It Means for You | |
|---|---|---|---|---|---|
| DG Set | Power Rating | 40kVA / 32kW | 45kva / 36kw | 60kva / 48kw | |
| Emission Norms | CPCB IV+ Compliant | CPCB IV+ Compliant | CPCB IV+ Compliant | ||
| Fuel Consumption | ~6.3 Ltrs/Hr @ 75% Load | ~6.3 Ltrs/Hr @ 75% Load | ~9.5 Ltrs/Hr @ 75% Load | ||
| B-Check Interval. Hours/ Months | 700Hr or 1 year which ever is earlier | 700Hr or 1 year which ever is earlier | 700Hr or 1 year which ever is earlier | ||
| Control Panel (Mode) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | ||
| Genset Dimensions (LXBXH) | 2500x1100x1300 | 2500x1100x1300 | 2800x1100x1500 | ||
| Genset Weight (kg) | 1162Kg | 1162Kg | 1282Kg | ||
| Engine Make | VECV (Volvo Eicher) | VECV (Volvo Eicher) | VECV (Volvo Eicher) | ||
| Engine | Cooling System | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | |
| Governor Type | Electronic (A1 Class) | Electronic (A1 Class) | Electronic (A1 Class) | ||
| Block Load Cap | Over 60% Sudden Load Capacity | Over 60% Sudden Load Capacity | Over 60% Sudden Load Capacity | ||
| Configuration | 4-Cylinder, Inline | 4-Cylinder, Inline | 4-Cylinder, Inline | ||
| Aspiration | Turbocharged intercooled | Turbocharged intercooled | Turbocharged intercooled | ||
| Alternator | Alternator Make | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | |
| Voltage Regulation | ± 1% (Static) | ± 1% (Static) | ± 1% (Static) | ||
| Insulation Class | Class H | Class H | Class H |
Enclosure & Build Quality
Engineered for extreme durability, our enclosures feature heavy-duty galvanized steel, anti-corrosive powder coating, and premium acoustic insulation for maximum weather protection and ultra-silent operation.
Sheet Metal
1.5mm Heavy-Duty CRCA sheet (Competition typically use 1.2mm).
Surface Treatment
9-Tank Pre-treatment with UV-Resistant Pure Polyester Powder Coating.
Hardware
Stainless Steel hinges and Zinc-plated fasteners for corrosion resistance
Insulation
High-density fire-retardant acoustic foam for Ultra-Silent Operation.
Frequently Asked Questions
Find expert answers to common questions regarding CPCB IV+ norms, DG set maintenance, and kVA load calculation. Get the clarity you need to make an informed investment in your facility’s backup power infrastructure.
What is the fuel consumption of a 60 kVA diesel generator?
An 60 kVA DG set typically consumes 10–12 liters of diesel per hour at 75% load. At full 100% load, consumption is approximately 14–15 liters per hour. Elmot PowerGen engines are engineered to maintain high efficiency even at variable loads.
How many AMPS does a 60 kVA 3-phase generator produce?
At 415 V, a 60 kVA three-phase generator can supply approximately 83.5 Amps per phase at full load. In practice, generators are typically operated below their maximum capacity to accommodate motor starting currents, load fluctuations, and future expansion. As a result, a 60 kVA generator is generally well suited for facilities with a sustained operating load of around 50–65 Amps per phase, depending on the nature of the connected equipment.
Can a 60 kVA generator run a 20 HP motor?
Yes, a 60 kVA generator can easily start and run a 20 HP induction motor. However, if the motor starts under heavy load, using a VFD (Variable Frequency Drive) or a Star-Delta starter is recommended to prevent excessive voltage dips.
Is the 60 kVA generator CPCB IV+ compliant?
Absolutely. All 60 kVA units from Elmot PowerGen are CPCB IV+ compliant, meeting the latest 2026 environmental standards. This includes advanced emission control systems that reduce smoke and harmful gases, ensuring 100% legality across all Indian states.
What is the noise level of a "Silent" 60 kVA DG set?
In accordance with CPCB guidelines, Elmot’s 60 kVA silent generators maintain a noise level of less than 75 dB(A) at a distance of 1 meter. Our acoustic enclosures use high-grade insulation to make them suitable for quiet office environments.
How many 1.5-ton ACs can a 60 kVA generator handle?
A 60 kVA generator can comfortably power 10 to 12 units of 1.5-ton 5-star inverter ACs, along with standard office lighting, computers, and a server room. It is the most popular choice for bank branches and mid-sized clinics.
What are the dimensions of a 60 kVA silent DG set?
The footprint for a silent 60 kVA generator is approximately 2600mm (L) x 1100mm (W) x 1500mm (H). Ensure your installation site has at least 1.5 meters of clear space on all sides for airflow and ease of maintenance.
What is the difference between a 60 kVA and a 62.5 kVA generator?
Technically, the difference is minimal (approx. 3.5 Amps). Many manufacturers use 62.5 kVA as a standard rating. Elmot PowerGen’s 60 kVA range is built with high-torque engines to provide the same reliable performance as 62.5 kVA units.
How often does a 60 kVA generator require an oil change?
A full oil and filter change (B-Check) is required every 300 to 500 running hours or every 6 months, whichever comes first. Using genuine Elmot spare parts and recommended oil grades ensures the longevity of the engine.
Does a 60 kVA generator need an Automatic Transfer Switch (ATS)?
For businesses like clinics or IT offices, an ATS (or AMF Panel) is highly recommended. it automatically switches the load to the 60 kVA generator within 10 seconds of a power failure, preventing data loss or equipment shutdown.
Is a 60 kVA generator suitable for a medium-sized cold storage?
Yes. A 60 kVA unit is ideal for small to medium cold storage units or supermarkets, as it can handle the high-starting torque required by refrigeration compressors and cooling fans.
What is the warranty on Elmot 60 kVA generators?
Elmot PowerGen offers a 2-year / 5000-hour comprehensive warranty. We also provide a 6-hour on-site service guarantee in our core regions (Telangana, AP, Karnataka, etc.) to ensure zero business interruption.
Can you provide a AMF panel for my genset? Please help me understand the benefit of the AMF panel vs using a UPS and manual switching?
Yes, ELMOT PowerGen can provide an AMF (Automatic Mains Failure) panel with compatible gensets. Before deciding, it's important to understand what an AMF panel does and how it differs from a UPS and manual switching.
An AMF panel continuously monitors the utility power supply and automatically detects an outage. It starts the generator and transfers the load from mains to generator through a changeover mechanism. Similarly, when utility power returns the load is automatically transferred back to the grid and shuts the generator.
Using a UPS and manual switching requires human intervention or notice and outage and start a generator.
I have some equipment that draw high power but are only used for few minutes to an hr at a time. Do I need to take a higher power Genset for this purpose?
Not necessarily. The key question is not:
"How much power does it require while starting and what other loads are running at the same time?"
Before selecting a generator, identify:
- Running kW of each load
- Motor sizes (HP/kW)
- Starting method (DOL, Star-Delta, Soft Starter, VFD)
- Which loads operate simultaneously
- Which loads are critical during backup operation
In many cases, customers can save money by using load sequencing, VFDs, or soft starters rather than purchasing a significantly larger genset solely for equipment that runs occasionally.
Reliable Energy for Every Industry
Secure your operations with precision-engineered 40-62.5 kVA DG sets. We deliver fuel-efficient, high-performance power that never skips a beat.