Unstoppable 10 to 30 kVA Power for Large Villas, Farmhouses, Telecom Towers and Petrol Pumps
From the comfort of your villa to the productivity of your farmhouse, ensure 24/7 reliability with our 10–30 kVA DG sets. Compact, silent, and built to perform.
Suitable Industries & Applications
Find the perfect power match for your sector. We provide tailored 10-30 kVA backup solutions designed to meet the unique load demands of diverse industries across South India.

Large Villas
Seamless power for luxury residences and vital connectivity.

Farmhouses
Robust power for premium estates and critical remote infrastructure.

Telecom Towers
Ensuring 24/7 uptime for essential communication and service networks.

Petrol Pumps
Constant power for critical connectivity and fueling infrastructure.
Elmot PowerGen Highlights
Unmatched fuel efficiency, optional IOT monitoring (on request), and localized manufacturing make Elmot PowerGen the smartest choice for backup power. Explore the technical highlights that set our 10 – 30 kVA diesel generators apart, ensuring lower total cost of ownership and 100% emission compliance.
Engine Technology
Escorts/VECV
Emission Standard
CPCB IV +
Enclosure
UV resistant coating - ideal for harsh environments
Maximum Uptime
Reliable, uninterrupted power performance
Service Response
2–3 Hrs (Local) / 6–24 Hrs (Remote)
Noise Level
<75 db(A) Ideal for residential areas
Minimum Fuel Burn
Optimized efficiency, lower fuel consumption
Technical Spotlight
Explore the cutting-edge engineering behind Elmot PowerGen’s 10-30 kVA range, featuring CPCB IV+ compliance and smart-load sensing.
See how our advanced fuel-mapping technology delivers maximum uptime with whisper-quiet performance.
| Feature | 10 kVA | 15 kVA | 20 kVA | 25 kVA | |
|---|---|---|---|---|---|
| DG Set | Power Rating | 10kva/8kw | 15kva/12kw | 20kva/16kw | 25kva/20kw |
| Emission Norms | CPCB IV+ Compliant | CPCB IV+ Compliant | CPCB IV+ Compliant | CPCB IV+ Compliant | |
| Fuel Consumption | 2.1 Ltrs/Hr @ 75% Load | 2.8 Ltrs/Hr @ 75% Load | 4.4 Ltrs/Hr @ 75% Load | 5.2 Ltrs/Hr @ 75% Load | |
| B-Check Interval. Hours/ Months | 500Hr or 3 months which ever is earlier | 500Hr or 3 months which ever is earlier | 500Hr or 3 months which ever is earlier | 500Hr or 3 months which ever is earlier | |
| Control Panel (Mode) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | |
| Genset Dimensions (LXBXH) | 1700x1000x1250 | 1700x1000x1250 | 1900 X 1000 X 1350 | 1900 X 1000 X 1350 | |
| Genset Weight (kg) | 797Kg | 816Kg | 830Kg | 935Kg | |
| Engine Make | Escorts kubota | Escorts kubota | Escorts kubota | Escorts kubota | |
| Engine | Cooling System | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) |
| Governor Type | Mechanical ("A1") | Mechanical ("A1") | Mechanical ("A1") | Electronic ("A1") | |
| Block Load Cap | Over 50% Sudden Load Capacity | Over 50% Sudden Load Capacity | Over 50% Sudden Load Capacity | Over 50% Sudden Load Capacity | |
| Configuration | 2-Cylinder, Inline | 2-Cylinder, Inline | 2&3Cylinder, Inline | 2&3Cylinder, Inline | |
| Aspiration | NA | NA | NA | Turbocharged intercooled | |
| Alternator | Alternator Make | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE |
| Voltage Regulation | ± 1% (Static) | ± 1% (Static) | ± 1% (Static) | ± 1% (Static) | |
| Insulation Class | Class H | Class H | Class H | Class H |
| Feature | 25 kVA | 30 kVA | What It Means for You | |
|---|---|---|---|---|
| DG Set | Power Rating | 20kva/20kw | 30kva/24kw | |
| Emission Norms | CPCB IV+ Compliant | CPCB IV+ Compliant | ||
| Fuel Consumption | ~3.9 Ltrs/Hr @ 75% Load | ~4.7 Ltrs/Hr @ 75% Load | ||
| B-Check Interval. Hours/ Months | 700Hr or 1 year which ever is earlier | 700Hr or 1 year which ever is earlier | ||
| Control Panel (Mode) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | ||
| Genset Dimensions (LXBXH) | 2500x1100x1300 | 2500x1100x1300 | ||
| Genset Weight (kg) | 979 Kg | 979 Kg | ||
| Engine Make | VECV (Volvo Eicher) | VECV (Volvo Eicher) | ||
| Engine | Cooling System | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | |
| Governor Type | Electronic (A1 Class) | Electronic (A1 Class) | ||
| Block Load Cap | Over 60% Sudden Load Capacity | Over 60% Sudden Load Capacity | ||
| Configuration | 4-Cylinder, Inline | 4-Cylinder, Inline | ||
| Aspiration | Turbocharged intercooled | Turbocharged intercooled | ||
| Alternator | Alternator Make | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | |
| Voltage Regulation | ± 1% (Static) | ± 1% (Static) | ||
| Insulation Class | Class H | Class H |
Enclosure & Build Quality
Engineered for extreme durability, our enclosures feature heavy-duty galvanized steel, anti-corrosive powder coating, and premium acoustic insulation for maximum weather protection and ultra-silent operation.
Sheet Metal
1.5mm Heavy-Duty CRCA sheet (Competition typically use 1.2mm).
Surface Treatment
7-Tank pretreatment and pure polyester powder coating for superior durability and corrosion resistance
Hardware
Stainless Steel hinges and Zinc-plated fasteners for corrosion resistance
Insulation
High-density fire-retardant acoustic foam for Ultra-Silent Operation.
Frequently Asked Questions
Find expert answers to common questions regarding CPCB IV+ norms, DG set maintenance, and kVA load calculation. Get the clarity you need to make an informed investment in your facility’s backup power infrastructure.
What is the fuel consumption of a 10 kVA to 30 kVA diesel generator?
Fuel consumption varies by load: a 10 kVA unit uses approximately 2.5–3 liters/hr, while a 30 kVA unit consumes 5.5–6.5 liters/hr at 75% load. Elmot PowerGen engines are specifically tuned to maintain high efficiency even during low-load periods.
How many ACs can a 10 kVA, 20 kVA, and 30 kVA generator run?
- 10 kVA: Powers 2–3 units of 1.5-ton inverter ACs.
- 20 kVA: Powers 4–5 units of 1.5-ton inverter ACs.
- 30 kVA: Powers 6–8 units of 1.5-ton inverter ACs.
- Note: This assumes a balanced household or office load.
Is a 10–30 kVA generator suitable for residential use?
Yes, this range is the "Gold Standard" for residential backup. Because they are CPCB IV+ compliant and feature Ultra-Silent acoustic enclosures, they can be installed in villas and apartments without violating noise or emission laws.
What are the space requirements for a 10–30 kVA silent DG set?
These units are highly compact. A 10 kVA unit needs roughly 1500mm x 900mm, while a 30 kVA unit needs 2000mm x 950mm. We recommend a 1.5-meter clearance around the set for airflow and maintenance access.
Can these generators be installed on a rooftop?
Yes. Due to their optimized power-to-weight ratio, 10–30 kVA sets are frequently installed on rooftops. Elmot PowerGen provides specialized Anti-Vibration Mounts (AVM) to ensure zero vibration transfer to the building structure.
What is the difference between Single Phase and Three Phase in this range?
Single Phase (230V) is typical for standard homes, while Three Phase (415V) is required for elevators, central AC units, and industrial machinery. Elmot offers both configurations across the 10–30 kVA spectrum.
Are Elmot 10–30 kVA generators CPCB IV+ compliant?
Absolutely. Every unit in our 10–30 kVA range meets the 2026 CPCB IV+ emission norms. This ensures your generator is future-proof, eco-friendly, and compliant with all National Green Tribunal (NGT) guidelines.
How many AMPS does a 20 kVA and 30 kVA generator produce?
- A 20 kVA (3-phase) generator produces approximately 27.8 Amps per phase.
- A 30 kVA (3-phase) generator produces approximately 41.7 Amps per phase.
Does a small generator (10–30 kVA) need an AMF Panel?
While not mandatory, an AMF (Auto-Mains Failure) Panel is highly recommended for clinics and homes. It ensures that when the grid fails, the generator starts and restores power automatically in under 10 seconds.
What is the typical lifespan of a 10–30 kVA diesel generator?
With regular maintenance, an Elmot PowerGen DG set has a functional lifespan of 15 to 20 years. Our heavy-duty engine blocks are designed for long-term durability in the high-temperature climates of South India.
How often should I change the oil in my 10–30 kVA DG set?
We recommend a full service ("B-Check") every 500-700 running hours or every 6 months. Regular oil and filter changes prevent carbon buildup and maintain the 12% fuel-efficiency advantage of Elmot engines.
What is the warranty for the 10–30 kVA range?
Elmot PowerGen provides a 2-year / 5000-hour comprehensive warranty. Our service network across Telangana, AP, Karnataka, and Maharashtra ensures a technician can reach your site within a 6-hour window.
What is B-Check and why should I care?
A B-Check is a scheduled preventive maintenance service performed after a specified number of operating hours, typically between 500 and 700 hours for Elmot gensets. It is more comprehensive than routine inspections and focuses on ensuring the engine, alternator, fuel system, cooling system, and electrical components continue to operate reliably.
Most gensets spend 99% of their life waiting for a power outage. A B-Check helps identify small issues before they become failures during an emergency.
What does a governor do in a genset? What is the difference between a mechanical and electronic governor?
A governor is one of the most important components in a genset because it controls the engine speed, which directly determines the output frequency of the generator.
A mechanical governor uses flyweights, springs and mechanical linkages. They are generally lower in cost and have a simpler design. An electronic governor on the other hand uses a magnetic speed sensor, electronic controller & an electric actuator.
Electronic governors have a faster response time and are usually preferred for loading sharing and higher rating gensets.
What is Block Load Capacity?
Block Load Capacity is a genset's ability to accept a large load instantly in a single step while maintaining acceptable voltage and frequency limits. It is represented in %age of full load.
Consider a 125 kVA genset.
If its specification says:
Block Load Acceptance: 50%
it means the genset can accept:
- 50% × 125 kVA = 62.5 kVA
instantly in one step.
How do I calculate my fuel need? Can I get a larger fuel tank for my remote Villa to avoid refills?
Yes, you can get a larger fuel tank for a remote villa, but it should be sized safely and as per local fire/environment rules.
How to calculate fuel need
All gensets come with fuel consumption per hour of operation. General assumption is you are operating at 75% load.
Use this simple formula:
Fuel required = Fuel consumption per hour × Expected running hours × Safety margin
To calculate accurately, you need:
- Genset rating in kVA or kW
- Average load percentage
- Fuel consumption at that load
- Number of backup hours required
- Refill frequency desired
For villas, gensets often run at partial load, so fuel use may be much lower at night than during peak AC/pump usage.
Reliable Energy for Every Industry
Secure your operations with precision-engineered 10–30 kVA DG sets. We deliver fuel-efficient, high-performance power that never skips a beat.