Unstoppable 82.5 to 180 kVA Power for Hotels, Multiplexes, Schools and IT Offices
Engineered to sustain entire building ecosystems—from central air conditioning and elevators to massive server rooms and projection systems.
Suitable Industries & Applications
Ensure an uninterrupted experience for your guests, students, and employees. Our 82.5–180 kVA range provides the massive load-bearing capacity needed to power full campuses, hospitality suites, and tech hubs.

Hotels
Ensuring guest comfort with uninterrupted HVAC and elevator service.

Multiplexes
Continuous power for high-end projection, sound, and audience safety.

Schools
Powering digital classrooms and securing a safe campus environment.

Offices
Sustaining server uptime and productivity for a seamless workplace.
Elmot PowerGen Highlights
Unmatched fuel efficiency, IOT monitoring is standard from 82.5 kVA, and localized manufacturing make Elmot PowerGen the smartest choice for backup power. Explore the technical highlights that set our 82.5 –180 kVA diesel generators apart, ensuring lower total cost of ownership and 100% emission compliance.
Engine Technology
VECV with IOT monitoring
Emission Standard
CPCB IV +
Enclosure
Powder coated ideal for costal areas
Maximum Uptime
Reliable, uninterrupted power performance
6 Cylinder Advantage
Higher efficiency, smoother performance
Service Response
2–3 Hrs (Local) / 6–24 Hrs (Remote)
Noise Level
<75 db(A) Ideal for residential areas
Minimum Fuel Burn
Optimized efficiency, lower fuel consumption
Technical Spotlight
Explore the cutting-edge engineering behind Elmot PowerGen’s 10-200 kVA range, featuring CPCB IV+ compliance and smart-load sensing. See how our advanced fuel-mapping technology delivers maximum uptime with whisper-quiet performance.
| Feature | 82.5 kVA | 100 kVA | 125 kVA | 160 kVA | 180 kVA | What It Means for You | |
|---|---|---|---|---|---|---|---|
| DG Set | Power Rating | 82.5kva/65.6kw | 100kva/80kw | 125 kVA/100 kW | 160kva/128kw | 180kva/144kw | |
| Emission Norms | CPCB IV+ Compliant | CPCB IV+ Compliant | CPCB IV+ Compliant | CPCB IV+ Compliant | CPCB IV+ Compliant | ||
| Fuel Consumption | ~14.6 Ltrs/Hr @ 75% Load | ~17.5 Ltrs/Hr @ 75% Load | ~20.1 Ltrs/Hr @ 75% Load | ~27.1 Ltrs/Hr @ 75% Load | ~31.1 Ltrs/Hr @ 75% Load | ||
| B-Check Interval Hours/ Months | 700Hr or 1 year which ever is earlier | 700Hr or 1 year which ever is earlier | 700Hr or 1 year which ever is earlier | 700Hr or 1 year which ever is earlier | 700Hr or 1 year which ever is earlier | ||
| Control Panel (Mode) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | Manual (AMF Module is standard) | ||
| Genset Dimensions (LXBXH) | 3150x1150x1600 | 3150x1150x1600 | 3400x1250x1500 | 3900x1400x1800 | 3900x1400x1800 | ||
| Genset Weight (kg) | 1618Kg | 2016Kg | 2016Kg | 2380Kg | 2380Kg | ||
| Engine Make | VECV (Volvo Eicher) | VECV (Volvo Eicher) | VECV (Volvo Eicher) | VECV (Volvo Eicher) | VECV (Volvo Eicher) | ||
| Engine | Cooling System | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | Liquid Cooled (Radiator) | |
| Governor Type | Electronic (A1 Class) | Electronic (A1 Class) | Electronic (A1 Class) | Electronic (A1 Class) | Electronic (A1 Class) | ||
| Block Load Cap | Over 60% Sudden Load Capacity | Over 60% Sudden Load Capacity | Over 60% Sudden Load Capacity | Over 60% Sudden Load Capacity | Over 60% Sudden Load Capacity | ||
| Configuration | 4-Cylinder, Inline | 4-Cylinder, Inline | 6-Cylinder, Inline | 6-Cylinder, Inline | 6-Cylinder, Inline | ||
| Aspiration | Turbocharged intercooled | Turbocharged intercooled | Turbocharged intercooled | Turbocharged intercooled | Turbocharged intercooled | ||
| Alternator | Alternator Make | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | MECCALTE LEROY SOMER STAMFORD CROMPTON GREAVE | |
| Voltage Regulation | ± 1% (Static) | ± 1% (Static) | ± 1% (Static) | ± 1% (Static) | ± 1% (Static) | ||
| Insulation Class | Class H | Class H | Class H | Class H | Class H |
Enclosure & Build Quality
Engineered for extreme durability, our enclosures feature heavy-duty galvanized steel, anti-corrosive powder coating, and premium acoustic insulation for maximum weather protection and ultra-silent operation.
Sheet Metal
1.5mm Heavy-Duty CRCA sheet (Competition typically use 1.2mm).
Surface Treatment
9-Tank Pre-treatment with UV-Resistant Pure Polyester Powder Coating.
Hardware
Stainless Steel hinges and Zinc-plated fasteners for corrosion resistance
Insulation
High-density fire-retardant acoustic foam for Ultra-Silent Operation.
Smart Control System
Our IoT enabled controllers, offer real time fuel monitoring, 10-second auto-start, and predictive health alerts for 24/7 industrial uptime.

Engine Control Unit (ECU)
DEIF Controller

Monitoring
Integrated IoT Dashboard (Real-time fuel, load, and health tracking).

Safety
Auto-shutdown for High Water Temp, Low Oil Pressure, and low fuel.
Frequently Asked Questions
Find expert answers to common questions regarding CPCB IV+ norms, DG set maintenance, and kVA load calculation. Get the clarity you need to make an informed investment in your facility’s backup power infrastructure.
What is the fuel consumption of an 82.5 kVA diesel generator?
An 82.5 kVA DG set typically consumes 14–16 liters of diesel per hour at 75% load. At full 100% load, consumption increases to approximately 19–21 liters per hour. Elmot PowerGen uses precision electronic fuel injection to keep these costs at the lower end of the industry average.
How many AMPS does an 82.5 kVA 3-phase generator produce?
At a standard 0.8 power factor and 415V, an 82.5 kVA generator produces approximately 115 Amps per phase. This capacity is ideal for small industrial units and medium-sized commercial buildings.
Can an 82.5 kVA generator run a 30 HP motor?
Yes, an 82.5 kVA generator is well-suited to start and run a 30 HP induction motor. However, to prevent voltage dips during startup, we recommend using a Star-Delta starter or a Soft Starter.
Is the 82.5 kVA DG set CPCB IV+ compliant?
Yes. All new 82.5 kVA units manufactured by Elmot PowerGen are CPCB IV+ compliant. This ensures they meet the 2026 Indian emission standards for Nitrogen Oxides (NOx) and Particulate Matter (PM), making them legal for use in all green zones and urban centers.
What is the noise level of an 82.5 kVA silent generator?
As per CPCB norms, a "Silent" 82.5 kVA DG set must maintain a noise level of less than 75 dB(A) at 1 meter. Elmot’s high-density acoustic enclosures ensure these levels are met, making them suitable for use near residential areas and offices.
How many 1.5-ton ACs can an 82.5 kVA generator handle?
An 82.5 kVA generator can typically power 15 to 18 units of 1.5-ton 5-star inverter ACs, assuming a balanced load with other essential lighting and equipment. This makes it a popular choice for supermarkets and bank branches.
What are the dimensions of a silent 82.5 kVA DG set?
A typical 82.5 kVA silent generator has a footprint of approximately 2800mm (L) x 1150mm (W) x 1600mm (H). We recommend leaving at least 1.5 to 2 meters of clear space around the unit for proper ventilation and maintenance access.
What is the difference between an 82.5 kVA and a 100 kVA generator?
The primary difference is the load-bearing capacity. An 82.5 kVA set provides ~115 Amps per phase, while a 100 kVA set provides ~139 Amps. Choose 82.5 kVA if your peak load is consistently below 100 Amps to ensure better fuel efficiency and lower initial investment.
How often should I service my 82.5 kVA generator?
Routine "A-Checks" (oil and coolant levels) should be done daily. A full "B-Check" (changing oil, fuel filters, and air filters) is required every 300 running hours or every 6 months, whichever comes first.
Does an 82.5 kVA generator require a dedicated foundation?
Yes. To minimize vibration and noise, an 82.5 kVA generator should be installed on a level concrete PCC bed (typically 150mm to 300mm thick). This protects the engine and the enclosure from structural stress over time.
Is an 82.5 kVA generator enough for supermarkets, small factories, and medium-sized function halls?
Yes, an 82.5 kVA generator is the standard choice for supermarkets, small factories, and medium-sized function halls (up to 300–500 guests). It can easily manage heavy lighting, sound systems, and industrial kitchen equipment simultaneously.
What is the warranty on Elmot 82.5 kVA generators?
Elmot PowerGen provides a 2-year or 5000-hour comprehensive warranty. Additionally, our Hyderabad-based service team offers a 6-hour response guarantee to ensure your business operations never face prolonged downtime.
Reliable Energy for Every Industry
Secure your operations with precision-engineered 82.5–180 kVA DG sets. We deliver fuel-efficient, high-performance power that never skips a beat.
